新品 Automatic Transformer Test System 9560 (3-in1+AC Source) 場所 台北市, 台湾
新しい
Doubleclick to zoom in
売り手に連絡
追加の写真や情報を依頼する
仕様
- 状態
- 新品
- Test channel
- 21
- Excitation current
- 2mA-4.2A
- Open- circuit voltage
- 10V-5000V
- The no-load power
- 0.2-500VA(External AC Source)
- Frequency
- 10Hz-200kHz
- Frequency resolution
- 5 digits
- Basic accuracy
- ±0.1%
- Ac drive level
- 10mV-2Vrms
- Dc drive level
- 10mV-2V
- Output impedance
- 100Ω
- Turn
- 0.1 ~ 99999.9 turns
- Test mode
- Meter Mode / List Mode
- Parameters measurement
- Inductance (L)、Impedance (Z)、Capacitance (C)、Resistance (R)、Conductance (G)、Susceptance (B)、Admittance (Y)、Alternating Current Resistance (ACR)、Quality Factor (Q)、θ、Direct Current Resistance (DCR)、Leakage Inductance、Turn Ratio、Balance、Short Circuit
- L, lk
- 0.1nH ~ 9999.99H
- C
- 0.00001pF ~ 999.99mF
- Q,d
- 0.00001 ~ 99999
- Z,x,r
- 0.00001Ω ~ 99.9999MΩ
- Y
- 0.01nS ~ 99.9999S
- Θ
- -180°~ +180°
- Dcr
- 0.1mΩ ~ 99.999 MΩ
- Pin-short
- 12 pairs, between pin to pin
- Items
- AC Hi pot
- Output voltage
- 10V-5000V
- Voltage resolution
- 1V
- Voltage accuracy
- ±(3% of setting+5V)
- Test range
- 0.001-31mA
- Ac arcing detection
- 0-20
- Measuring time
- 0.1-999s
- Ramp time
- 0.1-10s
- Time resolution
- 0.1s
- Impulse voltage
- 200V-5000V
- Area comparison
- When layer short happened, the loss of power on coil increase, the resonance damping coefficient increase, resonance amplitude decrease, the total area decrease. These are the basic parameters we check layer calculating and comparing the deference of area between golden sample and DUT.Show by percentageAnalysis the power loss by this data.
- Area differential
- Add up the difference between normal wave and DUT wave call “ Area differential”.When layer short happened, the inductance reduce(similar the transformer). The wave phase change and the area differential also change. This will show “fail” on the instrument.However, the parameter might cause deviation because of the deviation of inductance, resonance phase shift. (Silicon steel product such as motor and traditional transformer is not suitable)By calculating and comparing the deference of area between golden sample and DUT. To determine the degree of waveform overlap.Compare the inductance by this.
- Waveform comparison
- Set a acceptable wave range, if the DUT’s wave is in this range shows “pass” otherwise, “fail”This parameter can judge both amplitude and phase of resonance wave. This can increase the detection capability of layer short.
- Corona
- In pulse test, the insulation defect will cause discharge and create corona. This function is able to count the times that corona happened base on the degree of deviation.Detect the discharge phenomenon on the coil.
- Flat
- If the layer short happened, the waveform will tremble. Therefore, the instrument will quantize and compared it.
- Stroage
- Unlimited storage (By The PC Link)
- Power supply
- Voltage 90Vac-125Vac或190Vac-250VacFrequency 47-63Hz
- Power consumption
- 1000VA/set
- Dimension (w*h*d)
- 600*1020*1555mm (W*H*D)
- Weight
- 9 Kg
- 6265/6266/6267
- 7703
- Power supply
- Voltage90Vac-125Vacor190Vac-250Vac
- Dimension (w*h*d)
- 435x145x522 mm (W*H*D)
- Interface
- RS-232、Handler、LAN、USB Host、EXT. I/O
- Displa
- Color Screen, 7" TFT(800*480)
- カテゴリー
- 変圧器 場所 台湾
- サブカテゴリ―
- Machinery
- サブカテゴリ― 2
- Transformer testing systems
- リスティングID
- 61150255