新品 3-in-1 Transformer Testing System Low Voltage+Safety+Impulse 場所 台北市, 台湾

仕様

状態
新品
Test channel
20
Frequency
10Hz-200kHz
Frequency resolution
5 digits
Basic accuracy
±0.1%
Ac drive level
10mV-2Vrms
Dc drive level
10mV-2V
Output impedance
100Ω
Turn
0.1 ~ 99999.9 turns
Test mode
Meter Mode / List Mode
Parameters measurement
Inductance (L)、Impedance (Z)、Capacitance (C)、Resistance (R)、Conductance (G)、Susceptance (B)、Admittance (Y)、Alternating Current Resistance (ACR)、Quality Factor (Q)、θ、Direct Current Resistance (DCR)、Leakage Inductance、Turn Ratio、Balance、Short Circuit
L, lk
0.1nH ~ 9999.99H
C
0.00001pF ~ 999.99mF
Q,d
0.00001 ~ 99999
Z,x,r
0.00001Ω ~ 99.9999MΩ
Y
0.01nS ~ 99.9999S
Θ
-180°~ +180°
Dcr
0.1mΩ ~ 99.999 MΩ
Pin-short
12 pairs, between pin to pin
Items
AC Hi pot
Output voltage
10V-5000V
Voltage resolution
1V
Test range
0.001-31mA
Ac arcing detection
0-20
Measuring time
0.1-999s
Ramp time
0.1-10s
Time resolution
0.1s
Impulse voltage
200V-5000V
Area comparison
When layer short happened, the loss of power on coil increase, the resonance damping coefficient increase, resonance amplitude decrease, the total area decrease. These are the basic parameters we check layer calculating and comparing the deference of area between golden sample and DUT.Show by percentageAnalysis the power loss by this data.
Area differential
Add up the difference between normal wave and DUT wave call “ Area differential”.When layer short happened, the inductance reduce(similar the transformer). The wave phase change and the area differential also change. This will show “fail” on the instrument.However, the parameter might cause deviation because of the deviation of inductance, resonance phase shift. (Silicon steel product such as motor and traditional transformer is not suitable)By calculating and comparing the deference of area between golden sample and DUT. To determine the degree of waveform overlap.Compare the inductance by this.
Waveform comparison
Set a acceptable wave range, if the DUT’s wave is in this range shows “pass” otherwise, “fail”This parameter can judge both amplitude and phase of resonance wave. This can increase the detection capability of layer short.
Corona
In pulse test, the insulation defect will cause discharge and create corona. This function is able to count the times that corona happened base on the degree of deviation.Detect the discharge phenomenon on the coil.
Flat
If the layer short happened, the waveform will tremble. Therefore, the instrument will quantize and compared it.
6265/6266/6267
7721
Built-in   stroage
128 sets
Power   supply
Voltage98Vac-132Vacor 195Vac-264Vac
Power    consumption
600VA/set
Dimension   (w*h*d)
344x145x343 mm (W*H*D)
Weight
9 Kg
Interface
RS-232、Handler、LAN、USB Host、EXT. I/O
Displa
Color Screen, 7" TFT(800*480)
サブカテゴリ―
Machinery
サブカテゴリ― 2
Transformer testing systems
リスティングID
72958846

説明

Low Voltage Electrical Test
Hi pot/ Insulation Test
Impulse Test (Layer Short Circuit)
20 Channels
Test Frequency (200k/500k/1MHz)

AC Voltage Output 5000V
DC Voltage Output 6000V
Insulation Resistance 12000MΩ