新品 Motor Rotor Testing System MT-6920 (24/48 Channel) 場所 台北市, 台湾

仕様

状態
新品
System
Benchtop
Function
Operate directly on the instrument
Production traceability management - implementing bar code/label printer/laser engraver
/
Store test file sets
100 sets (existing instruments)
Sharing test files between devices
Unable to share, recreate the file
Accessing test data
/
Uploading test data to a cloud database
/
User permission management" or "user access control
/
Cpk report
/
Customized cpk report according to customer requirements
/
Test channel
24/48
Dcr range
0.1mΩ-100kΩ
Measuring mode
4-Wire
Dcr accuracy
Low Resistance0.1mΩ-1Ω±(0.2%±1mΩ)High Resistance1Ω-100KΩ±0.1%
Ac output voltage
100V-3000V
Ac leakage current
0.001mA-10mA
Ac arcing detection
Detect gears from 0-9
Dc output voltage
100V-3000V
Dc leakage current
0.001mA-5mA
Dc arcing detection
Detect gears from 0-9
Ir output voltage
100V-1000V
Insulation resistance
1-9999MΩ
Measuring time
0.1-99.9s Continuously adjustable
Voltage accuracy
±(3% of setting+5V)
Impulse voltage (programmable)
200V-3000V
Impulse voltage accuracy
±2%
Total area comparison
When layer short happened, the loss of power on coil increase, the resonance damping coefficient increase, resonance amplitude decrease, the total area decrease. These are the basic parameters we check layer calculating and comparing the deference of area between golden sample and DUT.Show by percentageAnalysis the power loss by this data.
Differential area comparison
Add up the difference between normal wave and DUT wave call “ Area differential”.When layer short happened, the inductance reduce(similar the transformer). The wave phase change and the area differential also change. This will show “fail” on the instrument.However, the parameter might cause deviation because of the deviation of inductance, resonance phase shift. (Silicon steel product such as motor and traditional transformer is not suitable)By calculating and comparing the deference of area between golden sample and DUT. To determine the degree of waveform overlap.Compare the inductance by this.
Wave comparison
Set a acceptable wave range, if the DUT’s wave is in this range shows “pass” otherwise, “fail”This parameter can judge both amplitude and phase of resonance wave. This can increase the detection capability of layer short.
Corona comparison
In pulse test, the insulation defect will cause discharge and create corona. This function is able to count the times that corona happened base on the degree of deviation.Detect the discharge phenomenon on the coil.
Flat comparison
If the layer short happened, the waveform will tremble. Therefore, the instrument will quantize and compared it.
Test fixture
According to the test requirements
Indicator
Pass/Fail Screen Diaplay/Sound
Built-in storage
Storage of 100 rewritable data sets
Operation
Manual, RS-232
Power supply
Voltage
Frequency
50/60Hz
Power consumption
300VA
Environment
Temperature
Humidity
20-90%RH
Display
6920
7605
14 Kg
Dimension (w*h*d)
6920
6908
7 Kg
Weight
6920
Interface
RS-232
サブカテゴリ―
Machinery
サブカテゴリ― 2
Motor rotor testing system
リスティングID
72958884

説明

24/48 Channels
Hipot/Leakage Current
Insulation Resistance
Winding Layer short Test
Resistance Welding Test

Inductance Test
It can test multiple sets of DUTs simultaneously
4-Wire DC Resistance measurement will be more accurate than others
The Impulse/Surge with waveform comparison is a non-destructive analysis
Chinese/English screen could be switched arbitrarily