Wireless Charger Automatic Test System 9901
- メーカー: MICROTEST
Dc source power supply on transmitting side (tx): Measuring Range - voltage | Voltage accuracy: ±(0.025%+0.025%FS) | Voltage resolution: 0.02V | Measuring range - current: 0-20A | Current accuracy: 0.05%+0.05%FS ...
台北市, 台湾
Automatic Transformer Test System 9560 (3-in1+AC Source)
Test channel: 21 | Excitation current: 2mA-4.2A | Open- circuit voltage: 10V-5000V | The no-load power: 0.2-500VA(External AC Source) | Frequency: 10Hz-200kHz | Frequency resolution: 5 digits | Basic accuracy: ±0...
台北市, 台湾
LCR Meter 6360 Series 6363/6364/6365/6366/6367
Selection: 6363 | Frequency range: 1mHz-20kHz | Frequency setting: Continuity | Frequency output accuracy: ±0.01% | Frequency resolution: 5 Digits | Basic accuracy: ±0.05% | Ac drive level: Test Signal Voltage Le...
台北市, 台湾
LCR Meter 6365A/6367A Electrochemical Applications
Frequency: 0.1Hz-200kHz (6365A)0.1Hz-1MHz (6367A) | Frequency setting: Continuity | Frequency output accuracy: ±0.01% | Frequency resolution: 5 Digits | Basic accuracy: ±0.05% | Ac drive level: Test Signal Vol...
台北市, 台湾
Capacitor Analyzer 6632C 10MHz
Frequency: 10Hz-10MHz | Frequency range: 10Hz-10MHz | Frequency setting: Continuity | Frequency resolution: 100mHz, 6-bit Frequency Input | Frequency output accuracy: ±0.01% | Basic accuracy: ±0.08% (typical ±0.0...
台北市, 台湾
Power Meter 7130
Frequency range: Fundamental frequency of the PLL source is in the range of 20Hz ~ 480Hz | Basic measurement accuracy: ±0 . 0 5 % | Sampling rate: 5 0 0 k SP S | Meter mode: ● | Harmonic analysis: 100th-order har...
台北市, 台湾
Power Analyzer 7140
Frequency range: Fundamental frequency of the PLL source is in the range of 20Hz ~ 480Hz | Basic measurement accuracy: ±0 . 0 5 % | Sampling rate: 5 0 0 k SP S | Meter mode: ● | Harmonic analysis: 100th-order har...
台北市, 台湾
LCR Meter 6621 Series 1/3/5/10/20/30MHz
Frequency: 10Hz-1MHz | Frequency range: 10Hz-30MHz | Frequency setting: Continuity | Frequency resolution: ±0.01% | Frequency output accuracy: 100mHz, 6-bit Frequency Input | Basic accuracy: typical ±0.05% | Ac d...
台北市, 台湾
LCR Meter 6630 Series 1/3/5/10/20/30/50MHz
Frequency: 10Hz-1MHz | Frequency range: 10Hz-50MHz | Frequency setting: Continuity | Frequency resolution: ±0.01% | Frequency output accuracy: 100mHz, 6-bit Frequency Input | Basic accuracy: typical ±0.05% | Ac d...
台北市, 台湾
Impedance Analyzer 6632 Series 1/3/5/10/20/30/50MHz
Frequency: 10Hz-1MHz | Frequency range: 10Hz-50MHz | Frequency setting: Continuity | Frequency resolution: 100mHz, 6-bit Frequency Input | Frequency output accuracy: ±0.01% | Basic accuracy: ±0.08% (typical ±0.05...
台北市, 台湾
Impedance Analyzer 6632S Series 1/3/5/10/20/30/50MHz
Frequency: 10Hz-1MHz | Frequency range: 10Hz-50MHz | Frequency setting: Continuity | Frequency resolution: 100mHz, 6-bit Frequency Input | Frequency output accuracy: ±0.01% | Basic accuracy: ±0.08% (typical ±0.05...
台北市, 台湾